Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 13(1)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36671976

RESUMO

A highly sensitive, biocompatible, and scalable phosphorescent oxygen sensor formulation is designed and evaluated for use in continuous metabolite sensors for biological systems. Ethyl cellulose (EC) and polystyrene (PS) nanoparticles (NPs) stabilized with Pluronic F68 (PF 68), Polydimethylsiloxane-b-polyethyleneglycol methyl ether (PDMS-PEG), sodium dodecylsulfate (SDS), and cetyltimethylammonium bromide (CTAB) were prepared and studied. The resulting NPs with eight different surfactant−polymer matrix combinations were evaluated for physical properties, oxygen sensitivity, effect of changes in dispersion matrix, and cytotoxicity. The EC NPs exhibited a narrower size distribution and 40% higher sensitivity than PS, with Stern−Volmer constants (Ksv) 0.041−0.052 µM−1 for EC, compared to 0.029−0.034 µM−1 for PS. Notably, ethyl cellulose NPs protected with PF68 were selected as the preferred formulation, as they were not cytotoxic towards 3T3 fibroblasts and exhibited a wide phosphorescence lifetime response of >211.1 µs over 258−0 µM and ~100 µs over 2.58−0 µM oxygen, with a limit of detection (LoD) of oxygen in aqueous phase of 0.0016 µM. The EC-PF68 NPs were then efficiently encapsulated in alginate microparticles along with glucose oxidase (GOx) and catalase (CAT) to form phosphorescent nanoparticles-in-microparticle (NIMs) glucose sensing microdomains. The fabricated glucose sensors showed a sensitivity of 0.40 µs dL mg−1 with a dynamic phosphorescence lifetime range of 46.6−197.1 µs over 0−150 mg dL−1 glucose, with a glucose LoD of 18.3 mg dL−1 and maximum distinguishable concentration of 111.1 mg dL−1. Similarly, lactate sensors were prepared with NIMs microdomains containing lactate oxidase (LOx) and found to have a detection range of 0−14 mg dL−1 with LoD of 1.8 mg dL−1 and maximum concentration of 13.7 mg dL−1 with lactate sensitivity of 10.7 µs dL mg−1. Owing to its versatility, the proposed NIMs-based design can be extended to a wide range of metabolites and different oxygen-sensing dyes with different excitation wavelengths based on specific application.


Assuntos
Glucose , Nanopartículas , Ácido Láctico , Oxigênio , Luminescência , Glucose Oxidase
2.
Med Teach ; 45(4): 404-411, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36288735

RESUMO

BACKGROUND: In an arts integrated interdisciplinary study set to investigate ways to improve social accountability (SA) in medical education, our research team has established a renewed understanding of compassion in the current SA movement. AIM: This paper explores the co-evolution of compassion and SA. METHODS: The study used an arts integrated approach to investigate people's perceptions of SA in four medical schools across Australia, Canada, and the USA. Each school engaged approximately 25 participants who partook in workshops and in-depth interviews. RESULTS: We began with a study of SA and the topic of compassion emerged out of our qualitative data and biweekly meetings within the research team. Content analysis of the data and pedagogical discussion brought us to realize the importance of compassion in the practice of SA. CONCLUSIONS: The cultivation of compassion needs to play a significant role in a socially accountable medical educational system. Medical schools as educational institutions may operate themselves with compassion as a driving force in engaging partnership with students and communities. Social accountability without compassion is not SA; compassion humanizes institutional policy by engaging sympathy and care.


Assuntos
Educação Médica , Empatia , Humanos , Responsabilidade Social , Austrália , Canadá
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA